1 概述General
ADL400導(dǎo)軌式多功能電能表,是主要針對電力系統(tǒng),工礦企業(yè),公用設(shè)施的電能統(tǒng)計、管理需求而設(shè)計的一款智能儀表,產(chǎn)品具有精度高、體積小、安裝方便等優(yōu)點。集成常見電力參數(shù)測量及電能計量及考核管理,提供上48月的各類電能數(shù)據(jù)統(tǒng)計。具有2~31次分次諧波與總諧波含量檢測。帶有RS485通信接口,可選用MODBUS-RTU協(xié)議。該電力儀表可廣泛應(yīng)用于各種控制系統(tǒng),SCADA系統(tǒng)和能源管理系統(tǒng)中。產(chǎn)品符合IEC62053-21認(rèn)證。
ADL400is a smart meter designed for power supply system, industrial and mining enterprises and utilities to calculate the electricity consumption and manage the electric demand. It features the high precision, small size and simple installation. It integrates the measurement of all electrical parameters with the comprehensive electricity metering and management provides various data on previous 48months, checks the 31st harmonic content and the total harmonic content, realizes the remote communication and the remote control with switching input and relay output and boasts the alarm output. It is fitted with RS485 communication port and adapted to MODBUS-RTU.ADL400can be used in all kinds of control systems, SCADA systems and energy management systems. Themeter meet the related technical requirements of electronic meter in the IEC62053-21standards.
2 型號說明Type description

3 功能列表Function description
表1 功能說明列表
Table 1 Function description list
| 功能Function | 功能說明Function description | 功能配置Function provide |
| 電能計量Measurement of kWh |
有功電能計量(正、反向) Active kWh (positive and negative) |
■ |
|
無功電能計量(正、反向) Reactive kWh (positive and negative) |
■ | |
| A、B、C分相正向有功電能 | ■ | |
| 電量測量Measurement of electrical parameters | U、I | ■ |
| P、Q、S、PF、F | ■ | |
| 諧波測量Measurement ofharmonics |
2~31次諧波電壓電流 2~31STVoltage and current harmonic |
■ |
|
LCD顯示 LCD Display |
12位段式LCD顯示、背光顯示 12bits section LCD display, background light |
■ |
|
按鍵編程 Key programming |
3按鍵可編程通信、變比等參數(shù) 3keys to communication and set parameters |
■ |
|
脈沖輸出 Pulse output |
有功脈沖輸出 Active pulse output |
■ |
|
復(fù)費率及 附帶功能 Multi-tariffand functions |
支持4個時區(qū)、2個時段表、 14個日時段、4個費率 Adapt 4 time zones, 2 time interval lists, 14 time interval by day and 4 tariff rates |
□ |
|
最大需量及發(fā)生時間 Max demanded kWh and time happened |
□ | |
|
上48月、上90日歷史凍結(jié)數(shù)據(jù) Frozen data on last 48 months, last 90days |
□ | |
|
日期、時間 Date, time |
□ | |
|
通訊 Communication |
RS485接口, 支持Modbus Communication interface: RS485, Communication protocol: MODBUS-RTU |
■ |
4 技術(shù)參數(shù)Technical parameter
表2 技術(shù)參數(shù)說明
Table 2 technical parameter descriptions
| 項目 | 性能參數(shù) | ||
|
規(guī)格 Specification |
三相四線 3 phase 4 wires |
||
|
測 量 Measurement |
電 壓 Voltage |
參比電壓 Referencevoltage |
3×230/400V |
|
功耗 Consumption |
<10VA(單相)(Single phase) | ||
|
阻抗 Impedance |
>2MΩ | ||
|
精度等級 Accuracy class |
誤差±0.2%(Error±0.2%) | ||
|
電 流 Current |
輸入電流 Input current |
0.1-10(80)A(直接接入 Direct access model) | |
|
功耗 Consumption |
<1VA(單路額定電流)(Single?phase rated current) | ||
|
精度等級 Accuracy class |
誤差±0.2%(Error±0.2%) | ||
| 功率Power |
有功、無功、視在功率,誤差±0.5℅ Active, reactive, apparent power, error±0.5℅ |
||
| 電網(wǎng)頻率Frequency | 45~65Hz,誤差±0.2%(Error±0.2%) | ||
|
計 量 Measurement |
電能Energy |
準(zhǔn)確度等級C級 Accuracy class:C |
|
| 時鐘Clock | ≤0.5s/d | ||
|
數(shù) 字 信 號 Digit signal |
電量脈沖輸出 Energy pulse output |
1路有功光耦輸出 Oneactive photocoupleroutput |
|
|
脈沖 pulse |
脈沖寬度 Width of pulse |
80±20ms | |
|
脈沖常數(shù) Pulse constant |
400imp/kWh(與基本電流對應(yīng))(Correspond with the basic current) | ||
|
通 信 communication |
接口與通信規(guī)約 Interface and communication |
RS485口:Modbus RTU規(guī)約 RS485:Modbus RTU |
|
|
通信地址范圍 Range of communication address |
Modbus RTU:1~ 254; | ||
|
波特率 Baud rate |
1200bps~19200bps | ||
|
環(huán) 境 environment |
工作環(huán)境 work environment |
室內(nèi)(如需在戶外使用,請為電表配備防水防塵表箱) Indoor ( If it needs to be installed outdoors, please add a dustproof and waterproof shell ) |
|
|
工作溫度 Relative temperature |
-40℃to +70℃(直接接入Direct access model) | ||
|
相對濕度 Relative humidity |
≤95℅(無凝露)(No condensation) | ||
|
防護等級 IP Rating |
IP51 Must be installed in a suitable IP rated enclosure |
5 外形尺寸Dimension drawings

注:直接接入的接線力矩應(yīng)該在3-4N·m,經(jīng)互感器接入的接線力矩應(yīng)該在1.5-2N·m。
Note:The torque of direct connect should be3-4N·m,and the torque of connect via CT should be 1.5-2N·m.
6 接線與安裝Wiring and installing
6.1電壓電流接線示意圖Wiring sample of voltage and current

Fig2Three phase four lines connect via CT



安科瑞電氣股份有限公司
吳春紅18702111910
上海市嘉定區(qū)育綠路253號
審核編輯 黃宇
-
電表
+關(guān)注
關(guān)注
13文章
872瀏覽量
37571 -
MID
+關(guān)注
關(guān)注
1文章
51瀏覽量
11979
發(fā)布評論請先 登錄
精準(zhǔn)計量,連通北美:安科瑞陽臺光伏美規(guī)單相電表
揭秘MID電表:它和普通電表有啥不同?
安科瑞APM521:UL認(rèn)證硬核加持,一表雙裝解鎖計量靈活性!
MID證書篇 | 做海外電表生意怕踩合規(guī) “坑”?安科瑞資質(zhì)認(rèn)證明細(xì)幫你提前避開!
安科瑞DJSF1352-D系列一體化MID認(rèn)證直流電能表助力開啟新能源充電新時代
UL、CE、MID三重認(rèn)證,精準(zhǔn)掌控能源脈搏:安科瑞ADL400N-CT系列儲能計量表助力綠色能源管理升級
安科瑞ADL400導(dǎo)軌式電表安裝使用說明書
安科瑞直流計量方案,解決直流充電樁計量問題!
什么是光伏雙向電表?雙向電表有哪些應(yīng)用?
從認(rèn)證到市場認(rèn)可:安科瑞 MID 電能表成充電樁企業(yè)歐洲破局利器
出海電表必備認(rèn)證!UL/MID/CE/ROHS
安科瑞AGF-AE-D/200家庭儲能計量采集儀表——精準(zhǔn)計量,智能防逆流,助力家庭能源高效管理
安科瑞MID認(rèn)證雙向計量導(dǎo)軌電表
評論